Configure the global LLDP settings
You can specify LLDP settings that are globally applied to the switch.
To configure the global LLDP settings:
- Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
The System Information page displays.
- Select System > LLDP > Global Configuration.
The Global Configuration page displays.
- In the TLV Advertised Interval field, enter the interval in seconds to transmit LLDP frames.
The range is from 5 to 32768 secs. The default is 30 seconds.
- In the Hold Multiplier field, enter the multiplier for the value that you enter in the TLV Advertised Interval field, which determines the time-to-live (TTL) for LLDP notifications.
The range is from 2 to 10 secs. The default value is 4. As an example, if the value that you enter in the TLV Advertised Interval field is 30 and the value that you enter in the Hold Multiplier field is 4, the TTL for LLDP notifications is 120 seconds.
- In the Reinitialization Delay field, enter the delay before reinitialization starts.
The range is from 1 to 10 secs. The default is 2 seconds.
- In the Notification Interval field, enter the interval in seconds for the transmission of notifications.
The range is from 5 to 3600 secs. The default is 5 seconds.
- Click the Apply button.
Your settings are saved.
- To save the settings to the running configuration, click the Save icon.