Configure the global LLDP-MED settings

You can specify LLDP-MED settings that are globally applied to the switch.

To configure the global LLDP-MED settings:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select System > LLDP > LLDP-MED > Global Configuration.

    The Global Configuration page displays.

  3. In the Fast Start Repeat Count field, enter the number of LLDP PDUs that are transmitted when the protocol is enabled.

    The range is from (1 to 10). Default value of fast repeat count is 3.

    The Device Class field displays the switch MED classification. The switch is a Network connectivity device.

    The following four types of MED devices exist, of which the first three are endpoints:

    • Class I: Generic devices, which include IP communication controllers.

    • Class II: Media devices, which include conference bridges.

    • Class III: Communication devices, which include IP telephones.

    • Class IV: Network connectivity devices, which include LAN switches, routers, IEEE 802.1 bridges, and IEEE 802.11 WiFi access points.

  4. Click the Apply button.

    Your settings are saved.

  5. To save the settings to the running configuration, click the Save icon.