Display the status of the ports and switch

To display the status of the ports and switch:

  1. Launch a web browser.
  2. In the address field of your web browser, enter the IP address of the switch.
    The login page displays.
    Note: The default web browser protocol is HTTPS. Do not use HTTP to access the AV UI.
  3. In the Login Name field, enter admin as the user name, in the Password field, enter your local device password, and click the AV UI Login button.
    The first time that you log in, no password is required. However, you then must specify a local device password to use each subsequent time that you log in.

    The password must be 8 to 64 characters in length and must contain at least one uppercase letter, one lowercase letter, and one number. The following special characters are allowed: ! @ # $ % ^ & * ( ).

    To display the password, click the eye icon.

    The Overview page displays.

  4. If you use a switch stack, from the Stack Unit menu at the top of the page, select the switch to configure.
  5. To display detailed information about a port that is connected to a device, point to the port in the graphical display of the switch.

    A pop-up window displays information about multiple properties of the port.

  6. If the port legends do not display below the graphical display of the switch, select the Show Legends check box.

    The following table describes the ports legend.

    Legend Description
    Connected The port is connected to a device that is powered up.
    Connected & Powered The port is connected to a powered device (PD) that is receiving PoE from the switch.
    Error An error occurred on the port.
    Disabled The port is disabled.
    Available The port is not connected to a device but is available.
    Blocked The port is blocked. That is, STP blocked the port to prevent a loop.
    Admin Down The port is administratively down.
    Warning The port reached 98 percent of its ingress or egress transmit rate.
    PoE Depending on the switch model, the port is a PoE+ port.
    PoE Disabled PoE is disabled on the port (see Disable PoE for one or more interfaces).
    Force-Authorized 802.1X access authentication is enabled and the port authentication mode is Force-Authorized (see Port authentication).
    Force-Unauthorized 802.1X access authentication is enabled and the port authentication mode is Force-Unauthorized (see Port authentication).
    Authorized 802.1X access authentication is enabled and the port authentication status is Authorized.
    Unauthorized 802.1X access authentication is enabled and the port authentication status is Unauthorized.
    LAG The port is member of a LAG (see Link Aggregation).
    VLAN Trunk The port functions as a VLAN trunk. That is, the port is a tagged port that processes tagged VLAN traffic.
    Auto Trunk The port functions as an Auto-Trunk (see Auto-Trunk overview).
    Force Multicast This port is configured for forced multicast (see Configure the multicast mode for one or more ports).
    1G SFP Fiber Port Depending on the switch model, the port is a 1G SFP fiber port that can accept an SFP transceiver module.
    10G SFP+ Fiber Port Depending on the switch model, the port is a 10G SFP+ fiber port that can accept an SFP or SFP+ transceiver module.
    25G SFP28 Fiber Port Depending on the switch model, the port is a 25G SFP28 fiber port that can accept an SFP28 transceiver module.
    100G QSFP28 Fiber Port Depending on the switch model, the port is a 100G QSFP28 fiber port that can accept an QSFP28 transceiver module.
    Creston Device Connected Depending on the switch model, a Creston device is connected to the port.
    Visionary Device Connected Depending on the switch model, a Visionary device is connected to the port.
    NUCLEUS Device Connected Depending on the switch model, a NUCLEUS device is connected to the port.

    For more information about the ports, see Display detailed information about the physical ports and LAGs.

    The following table describes the information that displays in the Device Details section, Configured Profiles section, CPU Utilization graph, Memory Utilization graph, and Fans & Temperature section.

    Field or Graph Description
    Device Details
    Product Name

    M4300 by default. This field is fixed.

    Serial Number The serial number of the switch. This field is fixed.
    Model The model number of the switch. This field is fixed.
    Date & Time

    The configured or detected date and time (see Date and time settings).

    Country/Region This field does not apply to the switch (N/A).
    Base MAC Address The MAC address of the switch. This field is fixed.
    System Name The configured system name, if any (see Add a system name).
    Firmware Version The active main firmware version of the switch (see Update the firmware).
    AV UI Version The active firmware version for the AV UI. This firmware is included in the main firmware.
    Boot Version The active boot version of the switch. This firmware is included in the main firmware.
    System Uptime The period in days, hours, minutes, and seconds since the switch was last started.
    OOB IP Address

    The IP address for access to the main UI or AV UI over the out-of-band (OOB) port of the switch (see OOB port IP address).

    (This port is also referred to as the service port.)

    Management IP Address The management IP address for access to the main UI or AV UI over any Ethernet network port of the switch (see Management interface IP address).
    STP Network Redundancy The configured STP network redundancy mode of the switch (see Set the STP network redundancy for the switch).
    Configured Profiles

    For more information about network profiles, see Network profiles.

    Profile Name The name of the network profile.
    Profile Type

    The profile template on which the network profile is based.

    The profile template can be any of the preconfigured profile template ( for example, Data or Video, see Overview of preconfigured AV profile templates) or a custom profile template (see Custom AV profile templates).

    VLAN ID The VLAN ID that is assigned to the network profile.
    IP Address The IP address that is assigned to the network profile.
    # of Assigned Ports The number of ports that are assigned to the network profile.
    CPU Utilization The CPU utilization as a percentage of the CPU capacity.
    Memory Utilization The memory utilization as a percentage of the total memory.

    Fans & Temperature

    Fan (numbered) The number of internal fans depends on the switch model. The state of the fan must be Active. If the state is not Active, there might be a problem with the fan and the cooling.

    MAC (numbered)

    The temperature in Celsius that is measured by the MAC sensor. The maximum is 90°C. The number of MAC sensors depends on the switch model.
    System (unnumbered) The temperature in Celsius that is measured by the System sensor. The maximum is 90°C.
    Max Temperature

    The maximum temperature for normal operation of the switch.

    Note: If the switch exceeds this temperature, the operation of the switch might be limited, for example, PoE might be disabled. The fans are placed in Cool mode. To return the switch to normal operation, you must restart the switch. For more information, see the hardware installation guide.