Configure an sFlow receiver

You can configure one or more devices that must function as sFlow receivers. The sFlow source interface provides the connection to these devices.

To configure an sFlow receiver:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select Monitoring > sFlow > Advanced > sFlow Receiver Configuration.

    The sFlow Receiver Configuration page displays.

  3. Select the Receiver Index check box for a receiver.
  4. In the Receiver Owner field, specify the receiver owner.

    Specify the name of the owner or the device.

    By default, the time-out option is enabled but the time-out period is configured as 0, which means that sFlow sampling does not stop after it is enabled.

  5. To configure a time-out period, do the following:
    1. In the Receiver Timeout field, specify the time-out period in seconds after which sampling stops.

      The range is from 0 to 2147483647. A value of zero means that sFlow sampling does not stop after it is enabled.

    2. From the No Timeout menu, select False to enable the time-out sampling option.
      The default is False. If you select True, sampling does not time out and the time-out period is automatically set to the maximum of 2147483647.
      Note: If you select False and restart the switch, the switch deletes sFlow configuration. To keep the sFlow configuration during a restart, select True.
  6. In the Maximum Datagram Size field, specify the maximum number of data bytes that can be sent in a single sample datagram.

    The default value is 1400. The range is from 200 to 12188. To prevent fragmentation of the datagrams, we recommend that you do not set the datagram size too low.

  7. In the Receiver Address field, specify the IP address of the sFlow receiver.
  8. In the Receiver Port field, specify the destination port for sFlow datagrams.

    The default port number is 6343. The range is from 1 to 65535.

  9. Click the Apply button.

    Your settings are saved.

    The Receiver Datagram Version field displays 5 as the version of sFlow datagrams.

  10. To save the settings to the running configuration, click the Save icon.