Configure the global TACACS+ settings

You can configure the global TACACS+ settings for communication between the switch and a TACACS+ server.

To configure the global TACACS+ settings:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select Security > Management Security > TACACS > TACACS+ Configuration.

    The TACACS+ Configuration page displays.

  3. In the Key String field, specify the authentication and encryption key for TACACS+ communications between the switch and the TACACS+ server.

    The range is from 0 to 128. The key must match the key configured on the TACACS+ server.

  4. In the Connection Timeout field, specify the maximum number of seconds allowed to establish a TCP connection between the switch and the TACACS+ server.

    The range is from 1 to 30 seconds. The default is 5 seconds.

  5. From the Source Interface menu, select the source interface that must be used for TACACS+ communication. By default, the following options display in the menu:
    • None: The primary IP address of the originating (outbound) interface is used as the source address.

    • VLAN 1: The primary IP address of VLAN 1 is used as the source address. This is the default selection.

    • Service Port: The management port IP address is used as the source address.

    Depending on the configuration of your switch, the following options can display:

    • Another VLAN ID: The primary IP address of a VLAN other than VLAN 1 is used as the source address.

    • Routing interface: The primary IP address of a routing interface is used as the source address.

    • Routing VLAN: The primary IP address of a VLAN routing interface is used as the source address.

    • Routing loopback interface: The primary IP address of a routing loopback interface is used as the source address.

    • Different: For some features, Different can display. This means that the source interface is configured separately.

  6. Click the Apply button.

    Your settings are saved.

  7. To save the settings to the running configuration, click the Save icon.