Configure green Ethernet interface settings
You can configure green Ethernet settings for individual interfaces.
To configure the green Ethernet interface settings:
- Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
The System Information page displays.
- Select System > Management > Green Ethernet > Green Ethernet Interface Configuration.
The Green Ethernet Interface Configuration page displays.
- Select one or more interfaces by taking one of the following actions:
-
To configure a single interface, select the check box associated with the interface, or type the interface number in the Go To Interface field and click the Go button.
-
To configure multiple interfaces with the same settings, select the check box associated with each interface.
-
To configure all interfaces with the same settings, select the check box in the heading row.
-
- From the Auto Power Down mode menu, select Enable or Disable.
By default, this mode is disabled for the interface. When a port link is down, the underlying physical layer goes down for a short period and then checks for port link pulses again so that auto-negotiation remains possible. In this way, the switch saves power when no link partner is present for the port. If the Auto Power Down mode is not supported for the interface, N/A is displayed.
- From the EEE mode menu, select Enable or Disable.
By default, this mode is disabled for an interface. Energy Efficient Ethernet (EEE) combines the MAC with a family of physical layers that support operation in a low power mode. It is defined by the IEEE 802.3az standard. Lower power mode enables both the send and receive sides of the link to disable some functionality for power savings when lightly loaded. Transition to low power mode does not change the link status. Frames in transit are not dropped or corrupted in transition to and from a port in low power mode. Transition time is transparent to upper layer protocols and applications.
- Click the Apply button.
Your settings are saved.
- To save the settings to the running configuration, click the Save icon.