Configure and view the global 802.1AS settings

You can globally enable 802.1AS on the switch and configure local clock priorities. The 802.1AS feature calculates the time delay between devices on a link and maintains an accurate view of a network clock.

To configure and view the global 802.1AS settings on the switch:

  1. Open a web browser and log in to the switch. For more information, see Log in to the main UI with a known IP address.
    The System Information page displays.
  2. Select Switching > 802.1AS > Basic > 802.1AS Configuration.

    The 802.1AS Configuration page displays.

  3. To enable the feature, select the 802.1AS status Enable radio button.
  4. In the Local Clock Priority1 field, specify the first priority value of the local clock.

    The local clock is the clock for the switch as a time-aware bridge. Enter a number between 0 and 255 seconds. The default is 255 seconds.

  5. In the Local Clock Priority2 field, specify the second priority value of the local clock.

    Enter a number between 0 and 255 seconds. The default is 248 seconds.

  6. Click the Apply button.

    Your settings are saved.

  7. To save the settings to the running configuration, click the Save icon.

The following table describes the view-only fields on the page.

Table 1. 802.1AS configuration information

Field

Description

GrandMaster Capable

Identifies whether the grandmaster clock is active. The default is False.

Best Clock Identity

The MAC address of the best clock that the switch detected.

Best Clock Priority1

The first priority value of the best clock that the switch detected.

Best Clock Priority2

The second priority value of the best clock that the switch detected.

Steps to Best Clock

The number of links between the best clock and the switch. If the switch itself is the best clock, the value is zero.

Local Clock Identity

The MAC address of the local clock on the switch.

GM Change Count

The number of times the grandmaster clock changed.

Last GM Change Timestamp

The time when the most recent grandmaster clock change occurred.