B. Access the main UI to configure the switch
You can use a computer on the same subnet as the switch to access the main UI over the switch's default IP address.
- Configure your computer with a static IP address:
- For access over an Ethernet network port, use an IP address in the 169.254.0.0 subnet with subnet mask 255.255.0.0. For example, use 169.254.100.201.
- For access over the OOB port, use an IP address in the 192.168.0.0 subnet with subnet mask 255.255.0.0. For example, use 192.168.0.201.
- Connect an Ethernet cable from an Ethernet port on your computer to the OOB port or an Ethernet network port on the switch.
- Launch a web browser and enter the default IP address of the switch in the address field of the browser:
- Ethernet port: For access over an Ethernet network port, enter http://169.254.100.100.
- OOB port: For access over the OOB port, enter http://192.168.0.239.
The login page displays. - To log in for the first time, click the Main UI Login button.
The main UI login page displays in a new tab.
- Enter admin as the user name, leave the password field blank, and click the Login button.
On first login, you are required to specify a password.
- Specify a password and log in again using your new password.
- Configure the switch settings.
On each UI page, save any changes you make.Note: For information about using the main UI, including information about assigning a static IP address to the switch, see the user manual, which you can download by visiting https://www.netgear.com/support/enterprise/downloads.