Time Zone Commands

Use these commands to configure system time and date, time zone, and summer time.

Use the time zone commands to configure system time and date, time zone, and summer time (that is, daylight saving time). Summer time can be recurring or non-recurring.

clock set

M4250

M4350

This command sets the system time and date.

Format

clock set hh:mm:ss

clock set mm/dd/yyyy

Mode Global Config
Parameter Description
hh:mm:ss Enter the current system time in 24-hour format in hours, minutes, and seconds. The range is hours: 0 to 23, minutes: 0 to 59, seconds: 0 to 59.
mm/dd/yyyy Enter the current system date in the format month, day, year. The range for month is 1 to 12. The range for the day of the month is 1 to 31. The range for year is 2010 to 2079.

Command example:

CODE
(NETGEAR Switch) (Config)# clock set 03:17:00
(NETGEAR Switch) (Config)# clock set 11/01/2011

clock summer-time date

M4250

M4350

Use the clock summer-time date command to set the summer-time offset to Coordinated Universal Time (UTC). If the optional parameters are not specified, they are read as either 0 or \0, as appropriate.

Format clock summer-time date {date month year hh:mm date month year hh:mm}[offset offset] [zone acronym]
Mode Global Config
Parameter Description
date Day of the month. Range is 1 to 31.
month Month. Range is the first three letters by name; jan, for example.
year Year. The range is 2000 to 2097.
hh:mm Time in 24-hour format in hours and minutes. The range is hours: 0 to 23, minutes: 0 to 59.
offset The number of minutes to add during the summertime. The range is 1 to 1440.
acronym The acronym for the summer-time to be displayed when summertime is in effect. Up to four characters are allowed.

Command example:

CODE
(NETGEAR Switch) (Config)# clock summer-time date 1 nov 2011 3:18 2 nov 2011 3:18
(NETGEAR Switch) (Config)# clock summer-time date 1 nov 2011 3:18 2 nov 2011 3:18 offset
120 zone INDA

clock summer-time recurring

M4250

M4350

This command sets the summer-time recurring parameters.

Format clock summer-time recurring {week day month hh:mm week day month hh:mm} [offset offset] [zone acronym]
Mode Global Config
Parameter Description
EU The system clock uses the standard recurring summer time settings used in countries in the European Union.
USA The system clock uses the standard recurring daylight saving time settings used in the United States.
week Week of the month. The range is 1 to 5, first, last.
day Day of the week. The range is the first three letters by name; sun, for example.
month Month. The range is the first three letters by name; jan, for example.
hh:mm Time in 24-hour format in hours and minutes. The range is hours: 0 to 23, minutes: 0 to 59.
offset The number of minutes to add during the summertime. The range is 1 to 1440.
acronym The acronym for the summertime to be displayed when summertime is in effect. Up to four characters are allowed.

Command example:

CODE
(NETGEAR Switch) (Config)# clock summer-time recurring 2 sun nov 3:18 2 mon nov 3:18
(NETGEAR Switch) (Config)# clock summer-time recurring 2 sun nov 3:18 2 mon nov 3:18
offset 120 zone INDA

no clock summer-time

This command disables the summer time settings.

Format no clock summer-time
Mode Global Config

Command example:

CODE
(NETGEAR Switch) (Config)# no clock summer-time

clock timezone

M4250

M4350

Use this command to set the offset to Coordinated Universal Time (UTC). If the optional parameters are not specified, they will be read as either 0 or \0 as appropriate.

Format clock timezone {hours} [minutes minutes] [zone acronym]
Mode Global Config
Parameter Description
hours Hours difference from UTC. The range is -12 to +13.
minutes Minutes difference from UTC. The range is 0 to 59.
acronym The acronym for the time zone. The range is up to four characters.

Command example:

CODE
(NETGEAR Switch) (Config)# clock timezone 5 minutes 30 zone INDA

no clock timezone

Use this command to reset the time zone settings.

Format no clock timezone
Mode Global Config

Command example:

CODE
(NETGEAR Switch) (Config)# no clock timezone

show clock

M4250

M4350

Use this command to display the time and date from the system clock.

Format show clock
Mode Privileged EXEC

Command example:

CODE
(NETGEAR Switch) # show clock
15:02:09 (UTC+0:00) Nov 1 2011
No time source

Command example:

CODE
(NETGEAR Switch) # show clock
10:55:40 INDA(UTC+7:30) Nov 1 2011
No time source

show clock detail

M4250

M4350

Use this command to display the detailed system time along with the time zone and the summertime configuration.

Format show clock detail
Mode Privileged EXEC

Command example:

CODE
(NETGEAR Switch) # show clock detail

15:05:24 (UTC+0:00) Nov 1 2011
No time source

Time zone:
Acronym not configured
Offset is UTC+0:00

Summertime:
Summer-time is disabled

Command example:

CODE
(NETGEAR Switch) # show clock detail

10:57:57 INDA(UTC+7:30) Nov 1 2011
No time source

 Time zone:
 Acronym is INDA
 Offset is UTC+5:30

 Summertime:
 Acronym is INDA
 Recurring every year
 Begins on second Sunday of Nov at 03:18
 Ends on second Monday of Nov at 03:18
 Offset is 120 minutes
 Summer-time is in effect.