Power Management Commands

Use these commands to configure power management.

Note: Power management commands are supported on the M4350 series switches only. The M4250 series switches do not support power management commands.

power redundancy

M4350

This command enables the N+1 power redundancy feature on a switch with a dual PSU configuration. If this feature is enabled, only one PSU provides PoE power to the switch. If the PSU fails, the redundant PSU seamlessly takes over the supply of PoE power to the switch. If this command is disabled, N+1 is also disabled and both PSUs provide PoE power to the switch at the same time. In this situation, the PoE budget for the switch increases.

The unit-number argument specifies the PSU in the switch.

Default Disabled
Format power redundancy [unit-number]
Mode Global Config
Note:

If the total available power minus the total consumed power is less than what one PSU can supply, the switch does not enable the N+1 feature. Instead, it generates the following error message on the console and in the logging buffer:

Not enough power to enable N+1 feature. Total available power: <X>. Total consumption power: <Y>

no power redundancy

This command disables the N+1 power redundancy feature.

Format no power redundancy
Mode Global Config

show power redundancy

M4350

This command displays the power redundancy status.

Format show power redundancy
Mode Privileged EXEC

Command example:

CODE
(NETGEAR Switch)# show power redundancy
N+1 configuration: ............................ Disable
N+1 Active: ................................... No
Number of PSU: ................................ 1
Effective Number of PSU: ...................... 1

show power

M4350

This command displays the switch power usage.

The optional unit-number argument specifies the PSU in the switch.

Format show power [unit-number]
Mode Privileged EXEC

Command example:

CODE
(NETGEAR Switch) #show power

Unit : 1
Model Name:.................................... M4350-16V4C
Total Available power(W): ..................... 420
Total Power Module Slot Number:................ 2

Power                                    Power
Modules  Module                          Module
Slot     Name          Status            AC Input(V)
-------  ------------  ----------------  -----------
1                      Not Present
2        APS420W       Operational       100-240