power redundancy
M4350
This command enables the N+1 power redundancy feature on a switch with a dual PSU configuration. If this feature is enabled, only one PSU provides PoE power to the switch. If the PSU fails, the redundant PSU seamlessly takes over the supply of PoE power to the switch. If this command is disabled, N+1 is also disabled and both PSUs provide PoE power to the switch at the same time. In this situation, the PoE budget for the switch increases.
The unit-number argument specifies the PSU in the switch.
| Default | Disabled |
| Format | power redundancy [unit-number] |
| Mode | Global Config |
If the total available power minus the total consumed power is less than what one PSU can supply, the switch does not enable the N+1 feature. Instead, it generates the following error message on the console and in the logging buffer:
Not enough power to enable N+1 feature. Total available power: <X>. Total consumption power: <Y>
no power redundancy
This command disables the N+1 power redundancy feature.
| Format | no power redundancy |
| Mode | Global Config |
show power redundancy
M4350
This command displays the power redundancy status.
| Format | show power redundancy |
| Mode | Privileged EXEC |
Command example:
(NETGEAR Switch)# show power redundancy
N+1 configuration: ............................ Disable
N+1 Active: ................................... No
Number of PSU: ................................ 1
Effective Number of PSU: ...................... 1
show power
M4350
This command displays the switch power usage.
The optional unit-number argument specifies the PSU in the switch.
| Format | show power [unit-number] |
| Mode | Privileged EXEC |
Command example:
(NETGEAR Switch) #show power
Unit : 1
Model Name:.................................... M4350-16V4C
Total Available power(W): ..................... 420
Total Power Module Slot Number:................ 2
Power Power
Modules Module Module
Slot Name Status AC Input(V)
------- ------------ ---------------- -----------
1 Not Present
2 APS420W Operational 100-240