SNMP Commands

Use these commands to configure Simple Network Management Protocol (SNMP) on the switch.

You can configure the switch to act as an SNMP agent so that it can communicate with SNMP managers on your network.

snmp-server

M4250

M4350

This command sets the name and the physical location of the switch and the organization responsible for the network. The range for the name, loc and con parameters is from 1 to 31 alphanumeric characters.

Default none
Format snmp-server {sysname name | location loc | contact con}
Mode Global Config

snmp-server engineid local

M4250

M4350

This command changes the SNMPv3 engine ID on the switch. By default, the SNMP engine ID is based on the MAC address of the switch.

Note: If you change the SNMP engine ID, any existing SNMP configuration is deleted and you must reconfigure the SNMP configuration on the switch.
Default default
Format snmp-server engineid local {engineid-string | default}
Mode Global Config
Parameter Description
engineid-string The custom SNMPv3 engine ID (from 6 to 32 characters).
default The SNMPv3 engine ID is based on the MAC address of the switch.

no snmp-server engineid local

This command removes a custom SNMP engine ID.

Note: If you remove a custom SNMP engine ID, any existing SNMP configuration is deleted and you must reconfigure the SNMP configuration on the switch.
Format no snmp-server engineid local
Mode Global Config

snmp-server community

M4250

M4350

This command adds (and names) a new SNMPv1 or SNMPv2 community. A community name is associated with the switch and with a set of SNMP managers that manage the community with a specified privilege level. Community names in the SNMP community table must be unique. If multiple entries are made using the same community name, the first entry is kept and processed and all duplicate entries are ignored.

Format snmp-server community community-string [ipaddress {ipaddress [ipmask] | prefix/prefix-length}] [ro | rw | su] [view view-name]
Mode Global Config
Parameter Description
community-string The name (from 1 to 30 characters) of the new community.
ro The community receives read-only privileges, which lets a user view but not change any object values.
rw The community receives read and write privileges, which lets a user both view and change all object values.
su The community receives super user (administrator) privileges, which lets a user configure the switch.
view-name The name of the view (from 1 to 30 characters) to which the community is limited.

ipaddress

ipaddress

The IPv4 address from which the community is allowed access.

The SNMP community sends SNMP packets from this address. The address along with the client IP mask value denotes a range of IP addresses from which SNMP clients can use the community to access the device. A value of 0.0.0.0 allows access from any IP address. Otherwise, this value is ANDed with the mask to determine the range of allowed client IP addresses.

ipmask The optional client IP mask for an SNMP community. The SNMP community sends SNMP packets from an address with this client IP mask. The address along with the client IP mask value denotes a range of IP addresses from which SNMP clients can use the community to access the device. A value of 255.255.255.255 allows access from only one computer and specifies that computer’s IP address as the client IP address. A value of 0.0.0.0 allows access from any IP address.

ipaddress

prefix/prefix-length

The IPv6 address from which the community is allowed access. The SNMP community sends SNMP packets from this address.

no snmp-server community

This command removes an SNMPv1 or SNMPv2 community that you specify by entering the community string.

Format no snmp-server community community-string
Mode Global Config

snmp-server community-group

M4250

M4350

This command configures a community access string to permit access through the SNMPv1 and SNMPv2 protocols.

Format snmp-server community-group community-string group-name [ipaddress ipaddress]
Mode Global Config
Parameter Description
community-string The name of the community access string (from 1 to 20 characters) that becomes associated with the community group.
group-name The name of the community group (from 1 to 30 characters) with which the community access string must be associated.
ipaddress The IPv4 or IPv6 address from which the community group is allowed access.

no snmp-server community-group

This command removes a community access string.

Format no snmp-server community-group community-string
Mode Global Config

snmp-server host

M4250

M4350

This command configures an SNMPv1 or SNMPv2 host to which the switch can send traps.

Default No host
Format snmp-server host {ipaddr | ipv6addr | hostname} {informs [timeout seconds] [retries retries] | traps version {1 | 2}} community-string [udp-port port] [filter filter-name]
Mode Global Config
Parameter Description
ipaddr, ipv6addr, or hostname The IPv4 or IPv6 address or name of the host.
informs The switch sends SNMPv2 informs to the host. (The switch sends either informs or traps.)
seconds The period in seconds (from 1 to 300 seconds) that the switch waits for an acknowledgement before it sends the inform again. The default is 15 seconds.
retries The number of times (from 0 to 255) that the switch attempts to send the same inform. The default is 3 attempts.
traps The switch sends traps to the host. (The switch sends either traps or informs.)
1 The switch sends SNMPv1 traps.
2 The switch sends SNMPv2c traps.
community-string The community string (from 1 to 20 characters) that is sent as part of the notification.
port The SNMP trap receiver port. By default, the port number is 162, but you can specify another port number.
filter-name The filter name (from 1 to 30 characters) that is associated with the host. (You can use a filter to specify which traps are sent to the host.)

no snmp-server host

This command removes the traps or informs configuration for an SNMP host.

For information about the parameters, see the snmp-server host command.

Format no snmp-server host {ipaddr | ipv6addr | hostname} {traps version {1 | 2} | informs}
Mode Global Config

snmp-server v3-host

M4250

M4350

This command configures an SNMPv3 host to which the switch can send traps.

Default No host
Format snmp-server v3-host {ipaddr | ipv6addr | hostname} username {traps {auth | priv} | informs {auth | priv} [timeout seconds] [retries retries]} [udpport port] [filter filtername]
Mode Global Config
Parameter Description
ipaddr, ipv6addr, or hostname The IPv4 or IPv6 address or name of the host.
username The name of the user (from 1 to 30 characters). The user must be associated with a group that supports SNMPv3 and the access method that you configure for this command.
traps The switch sends traps to the host. (The switch sends either traps or informs.)
informs The switch sends informs to the host. (The switch sends either informs or traps.)
seconds The period in seconds (from 1 to 300 seconds) that the switch waits for an acknowledgement before it sends the inform again. The default is 15 seconds.
retries The number of times (from 0 to 255) that the switch attempts to send the same inform. The default is 3 attempts.
auth Authentication is required but encryption is not required.
noauth Neither authentication nor encryption is required (This is the default setting.)
priv Both authentication and encryption are required.
port The SNMPv3 trap receiver port. By default, the port number is 162, but you can specify another port number.
filter-name The filter name (from 1 to 30 characters) that is associated with the host. (You can use a filter to specify which traps are sent to the host.)

no snmp-server v3-host

This command removes the traps or informs configuration for an SNMPv3 host.

For information about the parameters, see the snmp-server v3-host command.

Format no snmp-server v3-host {ipaddr | ipv6addr | hostname} {traps | informs}
Mode Global Config

snmp-server group

M4250

M4350

This command creates a custom SNMP access group.

Default No custom groups, but generic groups exist for all SNMP versions and privileges.
Format snmp-server group group-name {v1 | v2 | v3 {auth | priv}} [notify notify-view] [read read-view] [write write-view]
Mode Global Config
Parameter Description
group-name The group name (from 1 to 30 characters).
v1 This group is allowed access to SNMPv1 only.
v2 This group is allowed access to SNMPv2c only.
v3 This group is allowed access to SNMPv3 only.
auth The group is allowed access to SNMPv3 only and only when authentication is enabled but encryption is disabled.
priv The group is allowed access to SNMPv3 only and only when both authentication and encryption are enabled.
read-view The name of the view (from 1 to 30 characters) that the group can access during GET requests.
write-view The name of the view (from 1 to 30 characters) that the group can access during SET requests.
notify-view The name of the view (from 1 to 30 characters) that the group can access when traps are sent.

no snmp-server group

This command removes an SNMP access group.

For information about the parameters, see the snmp-server group command.

Format no snmp-server group group-name {v1 | v2 | v3 {auth | priv}}
Mode Global Config

snmp-server user

M4250

M4350

This command creates an SNMPv3 user that can access the switch.

Default No default user
Format snmp-server user username groupname [remote {engineid-string | address {ipaddr | ipv6addr | hostname}}] [auth-sha512 authentication-password | auth-sha512-key sha512-key] {[priv-aes128 encryption-password | priv-aes128-key aes128-key]}
Mode Global Config
Parameter Description
username The name (from 1 to 30 characters) of the SNMPv3 user.
groupname The group name (from 1 to 30 characters) of which the SNMPv3 user is a member.
engineid-string The engine-id (from 6 to 32 characters) of the remote management station that this user will be connecting from.
ipaddr, ipv6addr, or hostname The IPv4 or IPv6 address or name of the remote management station that this user will be connecting from.
auth-sha512 Indicates that you must enter a password on the basis of which the switch can generate an SHA-512 key for authentication.
authentication-password The actual password (from 1 to 32 characters) that lets the switch automatically generate an SHA-512 key for authentication.
auth-sha512-key Indicates that you must enter (or copy) the SHA-512 key for authentication.
sha512-key The actual SHA-512 key for authentication. The key can be up to 128 characters. If you do not enter a key, the switch automatically generates a key.
priv-aes128 Indicates that you must enter a password on the basis of which the switch can generate an AES-128 HMAC-MD5-96 key for encryption.
encryption-password The actual password (from 1 to 32 characters) that lets the switch automatically generate an AES-128 HMAC-MD5-96 key for encryption.
priv-aes128-key Indicates that you must enter (or copy) the AES-128 HMAC-MD5-96 key for encryption.
aes128-key The actual AES-128 HMAC-MD5-96 key for encryption. The key can be up to 128 characters. If you do not enter a key, the switch automatically generates a key.

Command example:

CODE
(NETGEAR Switch)(Config)#snmp-server user test grp1 auth-sha512 priv-aes128

Enter Authentication Password:********
Confirm Authentication Password:********
Enter Encryption Password:********
Confirm Encryption Password:********

Command example:

CODE
(NETGEAR Switch)(Config)#snmp-server user test DefaultWrite auth-sha512-key
6991313bb623241c8f6f967fa28dff0265b4b57dfd07301be41024a791df01f412d1ad8bd8cde6ae6d66da7
61987657afe36efd788d021012564cf8ed2718351 priv-aes128-key
6991313bb623241c8f6f967fa28dff0265b4b57dfd07301be41024a791df01f412d1ad8bd8cde6ae6d66da7
61987657afe36efd788d021012564cf8ed2718351

no snmp-server user

This command removes an SNMPv3 user.

Format no snmp-server user username
Mode Global Config

snmp-server enable traps

M4250

M4350

This command enables the Authentication Flag.

Default enabled
Format snmp-server enable traps
Mode Global Config

no snmp-server enable traps

This command disables the Authentication Flag.

Format no snmp-server enable traps
Mode Global Config

snmp-server enable traps violation

M4250

M4350

This command enables the switch to send violation traps. The switch sends a violation trap if it receives a packet with a disallowed MAC address on a locked port.

Note: For information about port security commands, see Protected Port Commands.
Default disabled
Format snmp-server enable traps violation
Mode Global Config

no snmp-server enable traps violation

This command prevents the switch from sending violation traps.

Format no snmp-server enable traps violation
Mode Global Config

snmp-server enable traps linkmode

M4250

M4350

This command enables Link Up/Down traps for the entire switch. If enabled, the switch sends link traps only if the Link Trap flag setting that is associated with a port is enabled. For more information, see snmp trap link-status.

Default enabled
Format snmp-server enable traps linkmode
Mode Global Config

no snmp-server enable traps linkmode

This command disables Link Up/Down traps for the entire switch.

Format no snmp-server enable traps linkmode
Mode Global Config

snmp-server enable traps multiusers

M4250

M4350

This command enables multiple user traps. If the traps are enabled, the switch sends a multiple user trap if a user logs in to the terminal interface (EIA 232 or Telnet) while an existing terminal interface session is already established.

Default enabled
Format snmp-server enable traps multiusers
Mode Global Config

no snmp-server enable traps multiusers

This command disables multiple user traps.

Format no snmp-server enable traps multiusers
Mode Global Config

snmp-server enable traps stpmode

M4250

M4350

This command enables the switch to send new root traps and topology change notification traps.

Default enabled
Format snmp-server enable traps stpmode
Mode Global Config

no snmp-server enable traps stpmode

This command prevents the switch from sending new root traps and topology change notification traps.

Format no snmp-server enable traps stpmode
Mode Global Config

snmp-server enable traps mac-notification change

M4250

M4350

This command enables MAC notification traps or informs to be sent to the SNMP server. MAC notification traps are sent only when they are enabled on an interface using the snmp trap mac-notification change command when the snmp-server enable traps mac-notification change command is enabled.

Default disabled
Format snmp-server enable traps mac-notification change
Mode Global Config

no snmp-server enable traps mac-notification change

This command disables MAC notification traps or informs to be sent to the SNMP server.

Format no snmp-server enable traps mac-notification change
Mode Global Config

snmp-server enable traps captive-portal

M4250

M4350

This command enables captive portal traps or informs to be sent to the SNMP server. The specific captive portal traps are configured using the trapflags command in Captive Portal Config mode.

Default disabled
Format snmp-server enable traps captive-portal
Mode Global Config

no snmp-server enable traps captive-portal

This command disables captive portal traps or informs to be sent to the SNMP server.

Format no snmp-server enable traps captive-portal
Mode Global Config

show mac-address-table notification change

M4250

M4350

This command displays the MAC notification configuration and contents of the MAC notification history table. If you specify an interface, the command displays the status of SNMP trap for MAC notification for that interface.

To specify an actual interface or port, do the following:

  • For an M4250 series switch, use the argument slot/port.
  • For an M4350 series switch, use the argument unit/slot/port, as shown in the command format.
Format show mac-address-table notification change [interface unit/slot/port]
Mode Privileged EXEC

snmp-server filter

M4250

M4350

This command creates a filter entry that lets you limit which traps are sent to a host.

Default No filter entries
Format snmp-server filter filtername oid-tree {included | excluded}
Mode Global Config
Parameter Description
filtername The name for the filter (from 1 to 30 characters).
oid-tree The OID subtree that must be included in or excluded from the filter. You can specify a subtree by numericals (for example, 1.3.6.2.4), keywords (for example, system). You can also use asterisks to specify a subtree family (for example, 1.3.*.4).
included The subtree must be included in the filter.
excluded The subtree must be excluded from the filter.

no snmp-server filter

This command removes a filter that you must specify. In addition, you can also specify a subtree.

Format no snmp-server filter filtername [oid-tree]
Mode Global Config

snmp-server view

M4250

M4350

This command creates a new view or modifies an existing view that an SNMP group can use to determine which objects can be accessed by a community or user.

Default The switch automatically creates default view for default groups.
Format snmp-server view viewname oid-tree {included | excluded}
Mode Global Config
Parameter Description
viewname The name for the view (from 1 to 30 characters).
oid-tree The OID subtree that must be included in or excluded from the view. You can specify a subtree by numericals (for example, 1.3.6.2.4), keywords (for example, system). You can also use asterisks to specify a subtree family (for example, 1.3.*.4).
included The subtree must be included in the view.
excluded The subtree must be excluded from the view.

no snmp-server view

This command removes a view that you must specify. In addition, you can also specify a subtree.

Format no snmp-server view viewname [oid-tree]
Mode Global Config

snmp-server port

M4250

M4350

This command modifies the port that the switch uses to detect SNMP messages. By default, the switch uses UDP port 161 to detect SNMP messages.

Default 161
Format snmp-server port number
Mode Privileged EXEC

no snmp-server port

This command resets the port that the switch uses to detect SNMP messages. After you enter this command, the switch uses UDP port 161 to detect SNMP messages.

Format no snmp-server port
Mode Privileged EXEC

snmp-server trapsend

M4250

M4350

Use this command to set the UDP port to which traps are sent by the SNMP server.

Default 50505
Format snmp-server trapsend number
Mode Privileged EXEC

no snmp-server trapsend

Use this command to reset the UDP port to which traps are sent by the SNMP server to the default port of 50505.

Format no snmp-server trapsend
Mode Privileged EXEC

snmptrap source-interface

M4250

M4350

This command configures the global source interface (that is, the source IP address) for all SNMP communication between the SNMP client and the server.

To specify an actual interface or port, do the following:

  • For an M4250 series switch, use the argument slot/port.
  • For an M4350 series switch, use the argument unit/slot/port, as shown in the command format.
Format snmptrap source-interface {unit/slot/port | loopback loopback-id | serviceport | vlan vlan-id}
Mode Global Config
Parameter Description
unit/slot/port The unit identifier that is assigned to the switch.
loopback-id The loopback interface that you want to use as the source IP address. The range of the loopback ID is from 0 to 7.
serviceport The service port IP address is used.
vlan-id The VLAN interface that you want to use as the source IP address. The range of the VLAN ID is from 1 to 4093.

no snmptrap source-interface

This command removes the global source interface for all SNMP communication between the SNMP client and the server.

Format no snmptrap source-interface
Mode Global Config

This command disables link status traps for an interface.

Format no snmp trap link-status
Mode Interface Config

M4250

M4350

This command enables link status traps for all interfaces.

Format snmp trap link-status all
Mode Global Config

This command disables link status traps for all interfaces.

Format no snmp trap link-status all
Mode Global Config

snmp trap mac-notification change

M4250

M4350

This command enables MAC notification traps to be sent for an interface.

The added keyword causes a trap to be sent when an interface is added. The removed keyword causes a trap to be sent when an interface is removed. You can configure both keywords, one after the other.

Format snmp trap mac-notification change [added | removed]
Mode Interface Config

no snmp trap mac-notification change

This command disables MAC notification traps to be sent for an interface.

The added keyword stops a trap from being sent when an interface is added. The removed keyword stops a trap from being sent when an interface is removed. You can configure both keywords, one after the other.

Format no snmp trap mac-notification change [added | removed]
Mode Interface Config

show snmp-server

M4250

M4350

This command shows the UDP port to which the SNMP server is connected and on which the switch sends SNMP traps.

Format show snmp-server
Mode Privileged EXEC

Command example:

CODE
(NETGEAR Switch)#show snmp-server
SNMP Server Port............................... 161
SNMP Trap Send Port............................ 162

show snmp engineID

M4250

M4350

This command displays the configured SNMP engine ID.

Format show snmp engineID
Mode Privileged EXEC

show snmp

M4250

M4350

This command displays the SNMP configuration on the switch.

Format show snmp
Mode Privileged EXEC
Term Definition
Community tables
Community-String The community string for the entry. The community string is used by the SNMPv1 and SNMPv2 protocols to access the switch.
Community-Access The privilege level: Read only, Read write, or su (which means super user).
View Name The name of the view to which the community receives access.
IP Address The IP address from which access to the community is allowed.
IP Mask The IP mask associated with the IP address.
Community Group tables
Community-String The community string for the entry. The community string is used by the SNMPv1 and SNMPv2 protocols to access the switch.
Group Name The group to which the community is assigned.
IP Address The IP address from which the group can access the community.
IP Mask The IP mask associated with the IP address.
Host table for SNMPv1 and SNMPv2
Target Address The IP address of the host to which SNMPv1 or SNMPv2 traps or informs are sent.
Type The type of SNMPv1 or SNMPv2 messages that are sent (either traps or informs).
Community The community to which the SNMPv1 or SNMPv2 messages are sent.
Version The SNMP version (SNMPv1 or SNMPv2) of the messages.
UDP Port The number of the UDP port to which the SNMPv1 or SNMPv2 messages are sent.
Filter Name The name of the filter that limits the SNMPv1 or SNMPv2 messages for the host.
TO sec The period in seconds before SNMPv1 or SNMPv2 inform messages time out.
Retries The number of times that the switch attempts to send the same SNMPv1 or SNMPv2 inform message.
Host table for SNMPv3
Target Address The IP address of the host to which SNMPv3 traps or informs are sent.
Type The type of SNMPv3 messages that are sent (either traps or informs).
User Name The name of the SNMPv3 user to which access is granted.
Security Level The privilege level that is assigned to the SNMPv3 user.
UDP Port The number of the UDP port to which the SNMPv3 messages are sent.
Filter Name The name of the filter that limits the SNMPv3 messages for the host.
TO sec The period in seconds before SNMPv3 inform messages time out.
Retries The number of times that the switch attempts to send the same SNMPv3 inform message.

show snmp filters

M4250

M4350

This command displays either all filters that are used when SNMP messages are sent or a specific filter that you must enter.

Format show snmp filters [filtername]
Mode Privileged EXEC
Term Definition
Name The name of the filter.
OID Tree The name of the OID subtree.
Type Shows if the OID tree is included in or excluded from the filter.

show snmp group

M4250

M4350

This command displays either all SNMP groups or a specific SNMP group that you must enter.

Format show snmp group [groupname]
Mode Privileged EXEC
Term Definition
Name The name of the group.
Context Prefix The name of the context that is associated with the group.
Security Model The protocol that can access the switch through the group.
Security Level The security level that is allowed for the group.
Views Read The view that this group provides read-access to.
Views Write The view that this group provides write-access to.
Views Notify The view that this group provides trap-access to.

show snmp user

M4250

M4350

This command displays either all SNMPv3 users or a specific SNMPv3 user that you must enter.

Format show snmp user [username]
Mode Privileged EXEC
Term Definition
Name The name of the user.
Group Name The name of the group to which the user is assigned and that defines the SNMPv3 settings.
Auth Meth The authentication method for the user.
Priv Meth The encryption method for the user.
Remote Engine ID The SNMP engine ID for the user device.

show snmp views

M4250

M4350

This command displays either all SNMP views or a specific SNMP view that you must enter.

Format show snmp views [viewname]
Mode Privileged EXEC
Term Definition
Name The name of the view.
OID Tree The name of the OID subtree.
Type Shows if the OID tree is included in or excluded from the view.

show trapflags (M4250 series switch)

M4250

This command displays the trap conditions. The command output shows all enabled trap flags.

Note: You can configure which traps the switch must generate by enabling or disabling the trap condition. If a trap condition is enabled and the condition is detected, the SNMP agent on the switch sends the trap to all enabled trap receivers. Cold and warm start traps are always generated and cannot be disabled.
Format show trapflags
Mode Privileged EXEC
Term Definition
Authentication Flag Indicates if an authentication failure trap is sent. By default, the flag is enabled.
Link Up/Down Flag Indicates if a link status trap is sent. By default, the flag is enabled.
Multiple Users Flag Indicates if a trap is sent when the same user ID is logged into the switch more than once at the same time (either through Telnet or the serial port). By default, the flag is enabled.
Spanning Tree Flag Indicates if a spanning tree trap is sent. By default, the flag is enabled.
ACL Traps Indicates if an ACL trap is sent. By default, the flag is disabled.
PIM Traps Indicates if a PIM trap is sent. By default, the flag is disabled.
Captive Portal Flag Indicates if a captive portal trap is sent. By default, the flag is disabled.
Power Supply Module state trap Indicates if a power supply mode state trap is sent. By default, the flag is enabled.
Temperature trap Indicates if a temperature trap is sent. By default, the flag is enabled.
Fan trap Indicates if a fan trap is sent. By default, the flag is enabled.
MAC Notification trap flag Indicates if a MAC notification trap is sent. By default, the flag is disabled.

show trapflags (M4350 series switch)

M4350

This command displays the trap conditions. The command output shows all enabled trap flags.

Note: You can configure which traps the switch must generate by enabling or disabling the trap condition. If a trap condition is enabled and the condition is detected, the SNMP agent on the switch sends the trap to all enabled trap receivers. Cold and warm start traps are always generated and cannot be disabled.
Format show trapflags
Mode Privileged EXEC
Term Definition
Authentication Flag Indicates if an authentication failure trap is sent. By default, the flag is enabled.
Link Up/Down Flag Indicates if a link status trap is sent. By default, the flag is enabled.
Multiple Users Flag Indicates if a trap is sent when the same user ID is logged into the switch more than once at the same time (either through Telnet or the serial port). By default, the flag is enabled.
Spanning Tree Flag Indicates if a spanning tree trap is sent. By default, the flag is enabled.
ACL Traps Indicates if an ACL trap is sent. By default, the flag is disabled.
DVMRP Traps Indicates if a DVMRP trap is sent. By default, the flag is disabled.
OSPFv2 Traps Indicates if an OSPFv2 trap is sent. By default, the flag is disabled. If any of the OSPFv2 trap flags are disabled, the command displays “disabled.” Otherwise, the command shows the information for all enabled OSPFv2 traps.
PIM Traps Indicates if a PIM trap is sent. By default, the flag is disabled.
OSPFv3 Traps Indicates if an OSPFv3 trap is sent. By default, the flag is disabled. If any of the OSPFv3 trap flags are disabled, the command displays “disabled.” Otherwise, the command shows the information for all enabled OSPFv3 traps.
Captive Portal Flag Indicates if a captive portal trap is sent. By default, the flag is disabled.
Power Supply Module state trap Indicates if a power supply mode state trap is sent. By default, the flag is enabled.
Temperature trap Indicates if a temperature trap is sent. By default, the flag is enabled.
Fan trap Indicates if a fan trap is sent. By default, the flag is enabled.
VRRP Traps Indicates if a VRRP trap is sent. By default, the flag is enabled.
MAC Notification trap flag Indicates if a MAC notification trap is sent. By default, the flag is disabled.