Configure STP and CST settings for one or more interfaces

You can configure the following interface settings that are related to STP and CST:

  • STP Mode: Lets you enable or disable the Spanning Tree Protocol administrative mode for the port or LAG. The default setting is enabled.
  • Admin STP Edge Port: Lets you enable or disable the port or LAG as an edge port in the Common and Internal Spanning Tree (CIST). The default setting is enabled.
  • TCN Guard: Lets you enable or disable the port or LAG from propagating any topology change information that it receives. The default setting is disabled.
  • BPDU Filter: Lets you enable or disable the BPDU Filter feature on the port or LAG. A BPDU filter normally applies to an operational edge port. An edge port in an operational state connects to hosts that typically drop BPDUs. If an operational edge port receives a BPDU, it loses its operational status. If a port on which BPDU filtering is enabled receives BPDUs, the port drops the BPDUs and remains operational. The default setting is disabled.

To configure STP and CST settings for one or more ports or LAGs:

  1. Launch a web browser.
  2. In the address field of your web browser, enter the IP address of the switch.
    The login page displays.
    Note: The default web browser protocol is HTTPS. Do not use HTTP to access the AV UI.
  3. In the Login Name field, enter admin as the user name, in the Password field, enter your local device password, and click the AV UI Login button.

    The first time that you log in, no password is required. However, you then must specify a local device password to use each subsequent time that you log in.

    The password must be 8 to 64 characters in length and must contain at least one uppercase letter, one lowercase letter, and one number. The following special characters are allowed: ! @ # $ % ^ & * ( ).

    To display the password, click the eye icon.

    The Overview page displays.

  4. Select Configure > Port configuration.
    The Port Interface Details page displays.
  5. (Single port or LAG) To configure STP and CST settings for an individual port or LAG, do the following:
    1. Select the check box for the port or LAG.
    2. From the STP Mode menu, Admin STP Edge Port menu, TCN Guard menu, and BPDU Filter menu for the port or LAG, select Enable or Disable.

      For more information about these menus, see the introduction to this procedure.

  6. (Multiple ports or LAGs) To configure STP and CST settings for multiple ports, LAGs, or both, do the following:
    1. Select the check boxes for the ports, LAGs, or both.
    2. From the STP Mode menu, Admin STP Edge Port menu, TCN Guard menu, and BPDU Filter menu in the table header row, select Enable or Disable.

      For more information about these menus, see the introduction to this procedure.

  7. (All ports and LAGs) To configure STP and CST settings for all ports and LAGs, do the following:
    1. Select the check box in the table header row.
    2. From the STP Mode menu, Admin STP Edge Port menu, TCN Guard menu, and BPDU Filter menu in the table header row, select Enable or Disable.

      For more information about these menus, see the introduction to this procedure.

  8. Click the Apply button.

    Your settings are saved.

  9. To save the settings to the running configuration, at the top of the page, click the Save icon or text.