Configure flow control for one or more interfaces

You can configure IEEE 802.3x flow control, which can help to prevent data loss when the port cannot keep up with the number of frames being switched:

  • Symmetric flow control: With symmetric flow control, the switch can send a pause frame to stop traffic on the port if the amount of memory used by the packets on the port exceeds a preconfigured threshold and responds to pause requests from partner devices. The paused port does not forward packets for the time that is specified in the pause frame. When the pause frame time elapses, or the utilization returns to a specified low threshold, the switch enables the port to again transmit frames.
  • Asymmetric flow control: With asymmetric flow control, the switch does not send pause frames, but does honor incoming pause frames by temporarily halting transmission.

To configure flow control for one or more ports:

  1. Launch a web browser.
  2. In the address field of your web browser, enter the IP address of the switch.
    The login page displays.
    Note: The default web browser protocol is HTTPS. Do not use HTTP to access the AV UI.
  3. In the Login Name field, enter admin as the user name, in the Password field, enter your local device password, and click the AV UI Login button.

    The first time that you log in, no password is required. However, you then must specify a local device password to use each subsequent time that you log in.

    The password must be 8 to 64 characters in length and must contain at least one uppercase letter, one lowercase letter, and one number. The following special characters are allowed: ! @ # $ % ^ & * ( ).

    To display the password, click the eye icon.

    The Overview page displays.

  4. Select Configure > Port configuration.
    The Port Interface Details page displays.
  5. (Single port) To configure flow control for an individual port, do the following:
    1. Select the check box for the port.
    2. From the Flow Control menu for the port, select what happens if the port buffers become full:
      • Disable: The switch does not send pause frames, and data loss could occur. This is the default setting.
      • Symmetric: The switch sends pause frames to stop traffic. The switch also honors incoming pause frames by temporarily halting transmission.
      • Asymmetric: The switch does not send pause frames, and data loss could occur. However, the switch does honor incoming pause frames by temporarily halting transmission.
  6. (Multiple ports) To configure flow control for multiple ports, do the following:
    1. Select the check boxes for the ports.
    2. From the Flow Control menu in the table header row, select what happens if the port buffers become full:
      • Disable: The switch does not send pause frames, and data loss could occur. This is the default setting.
      • Symmetric: The switch sends pause frames to stop traffic. The switch also honors incoming pause frames by temporarily halting transmission.
      • Asymmetric: The switch does not send pause frames, and data loss could occur. However, the switch does honor incoming pause frames by temporarily halting transmission.
  7. (All ports) To configure flow control for all ports, do the following:
    1. Select the check box in the table header row.
    2. From the Flow Control menu in the table header row, select what happens if the port buffers become full:
      • Disable: The switch does not send pause frames, and data loss could occur. This is the default setting.
      • Symmetric: The switch sends pause frames to stop traffic. The switch also honors incoming pause frames by temporarily halting transmission.
      • Asymmetric: The switch does not send pause frames, and data loss could occur. However, the switch does honor incoming pause frames by temporarily halting transmission.
  8. Click the Apply button.

    Your settings are saved.

  9. To save the settings to the running configuration, at the top of the page, click the Save icon or text.