Manually control the fans

The switch includes internal fans that support intelligent operation, which enables the switch to automatically start the operation of the fans, gradually increase the speed of the fans, and either halt PoE or block traffic if the temperature exceeds a critical level.

You can manually control the fans through either the AV UI (see the following procedure) or the command-line interface (CLI).

For the M4250 series switches, if the fans are functioning in Off mode (which you only can set manually) or in Quiet mode, the switch automatically manages the fans and turns on the fans or gradually increases the speed of the fans under the following conditions:

  • PoE+ and PoE++ models: Either the temperature detected by the temperature sensor exceeds its threshold or a PoE budget is exceeded.
  • LED tiles model (M4250-12M2XF): Either the temperature detected by the temperature sensor exceeds its threshold or the switch processes a full traffic load.
  • Aggregation model (M4250-16XF): Either the temperature detected by the temperature sensor exceeds its threshold or the switch processes a full traffic load.
Note: For detailed information about temperature thresholds, PoE budgets, and traffic load conditions that affect the fans, see the hardware installation guide, which you can download by visiting netgear.com/support/download.

To manually control the fans:

  1. Launch a web browser.
  2. In the address field of your web browser, enter the IP address of the switch.
    The login page displays.
    Note: The default web browser protocol is HTTPS. Do not use HTTP to access the AV UI.
  3. In the Login Name field, enter admin as the user name, in the Password field, enter your local device password, and click the AV UI Login button.

    The first time that you log in, no password is required. However, you then must specify a local device password to use each subsequent time that you log in.

    The password must be 8 to 64 characters in length and must contain at least one uppercase letter, one lowercase letter, and one number. The following special characters are allowed: ! @ # $ % ^ & * ( ).

    To display the password, click the eye icon.

    The Overview page displays.

  4. In the Fans & Temperature section, select one of the following radio buttons.
    • Off: The fans are off and produce no noise. You can only manually set the fans in Off mode. The following M4250 series models do not support Off mode.
      • M4250-26G4F-PoE++
      • M4250-40G8XF-PoE+
      • M4250-40G8XF-PoE++
    • Quiet: The fans function from 10, 20, or 25 percent (depends on the model) to 100 percent speed. Quiet mode is the default mode. At 10, 20, or 25 percent speed, the fans produce minimal noise. Fan noise increases at 50 percent speed and even more so at 75 percent speed. At 100 percent speed, the fans produce considerable noise.

      In Quiet mode, the switch might automatically change back and forth between Cool mode and Quiet mode until a temperature, PoE budget, or traffic load condition returns within thresholds.

    • Cool: The fans consistently function at 100 percent speed and produce maximum cooling as well as considerable noise.
    The fan setting changes immediately. However, depending on the switch model, if the temperature detected by the temperature sensor exceeds its threshold, a PoE budget is exceeded, or a traffic load condition is exceeded, the switch automatically overrides your manual setting.
  5. To save the settings to the running configuration, at the top of the page, click the Save icon or text.