PoE troubleshooting suggestions

Here are some tips for correcting Power over Ethernet (PoE) problems that might occur on switches that support PoE:

  • Make sure that the PoE Max LED is off. If the PoE Max LED is solid amber, disconnect one or more PoE devices to prevent PoE oversubscription.
  • Make sure that the Ethernet cables are plugged in correctly. For each powered device (PD) that is connected to the switch, the associated PoE port LED on the switch lights solid green. If the associated PoE port LED lights solid amber, a PoE fault occurred and PoE halted because of one of the conditions listed in the following table.
    Table 1. PoE fault conditions and possible solutions

    PoE Fault Condition

    Possible Solution

    A PoE-related short circuit occurred on the port.

    The problem is most likely with the attached PD. Check the condition of the PD or restart the PD by disconnecting and reconnecting the PD.

    The PoE power demand of the PD exceeded the maximum level that the switch permits. The maximum level is 15.4W for a PoE connection or 30W for a PoE+ connection.

    The PoE current on the port exceeded the classification limit of the PD.

    The PoE voltage of the port is outside the range that the switch permits.

    Restart the switch to see if the condition resolves itself.