Configure HTTPS access settings

You can choose to enable or disable web access to the switch's device UI through HTTPS for remote network administration. You must select the HTTPS port you want to use for remote access, set the session timeout, and maximum number of HTTPS sessions. HTTPS is disabled by default.

Note:

Secure HTTP (HTTPS) enables the transmission of HTTP over an encrypted Secure Sockets Layer (SSL) or Transport Layer Security (TLS) connection. When you manage the switch over the device UI, HTTPS can help ensure that communication between the management system and the switch is protected from eavesdroppers and man-in-the-middle attacks. The hash algorithms that SSL uses are MD5 and SHA-1.

Note: You can download SSL certificates only when HTTPS is disabled.

To configure the HTTPS access settings:

  1. Open a web browser from a computer that is connected to the same network as the switch, or connected directly to the switch through an Ethernet cable.
  2. Enter the IP address that is assigned to the switch.
    A login window opens.
  3. Enter the switch password.

    The password is the one that you specified the first time that you logged in. The password is case-sensitive.

    The HOME page displays.

  4. From the menu at the top of the page, select SETTINGS.
  5. From the menu on the left, select GUI ACCESS.
    The HTTPS Configuration page displays.
  6. Click the HTTPS Configuration tab.
  7. Click the Admin Mode button to enable or disable remote access through HTTPS.
    When this setting is enabled, the button displays on the right side of the slide, and the slide turns green.
  8. In the HTTPS Port field, type in the number of the port.
    The default is port 443, or you can set a number in the range from 1025 to 65535.
  9. In the HTTPS Session Timeout (Minutes) field, type the number of minutes that a session can be inactive before it times out.
    The default is 30. The range is 0 to 60.
  10. In the Maximum Number of HTTPS Sessions field, set the number of concurrent sessions allowed.
    The default is 4. The range is 1 to 4.
  11. When your settings are complete, click the APPLY button.
    Your settings are applied.