Monitor PD health

You can use powered device (PD) health monitoring to test the health of a PD that is connected to a PoE port. You can enable automated ping tests that check for connection faults, and you can restart PoE power to the PD.

Note: Wait a few minutes after attaching the PD before you start the PD health monitor.
Warning: To prevent corrupting firmware on a PD, be sure to disable PD health monitoring on the switch before you update the PD’s firmware. During a firmware update, the PD might not reply to a ping test, so disabling PD health monitoring ensures that the switch doesn’t restart the PD while a firmware update is in progress.

To display the status of the PD:

  1. Open a web browser from a computer that is connected to the same network as the switch, or connected directly to the switch through an Ethernet cable.
  2. Enter the IP address that is assigned to the switch.
    A login window opens.
  3. Enter the switch password.

    The password is the one that you specified the first time that you logged in. The password is case-sensitive.

    The HOME page displays.

  4. From the menu at the top of the page, select POE.
  5. From the menu on the left, select PD HEALTH MONITORING.
    The PD Health Monitoring page displays.
  6. Click the port where the PD that you want to test is connected.
    When the port is selected, the port button displays solid purple.
  7. Turn on the PD Health Monitoring toggle.
    When PD health monitoring is enabled, the toggle displays green.
    A status message displays to confirm whether the PD Health Monitor is ready.
    The PD IP Address field displays the IP address of the PD.
  8. In the Ping Time Interval field, enter the time interval in seconds for the ping test.

    The default value is 60 seconds.

  9. Turn on or off the If an error occurs while the PD Health Monitor is running, restart the PoE toggle.
    When enabled, the toggle displays green and is positioned on the right.
  10. Click to enable or disable the If the Restart Count is over 5 then disable PoE option. If you want to use a different count value, select 10 or 20 from the menu.
    The option is disabled by default, with the count set to 5.
  11. When your settings are complete, click the APPLY button.
    The ping test on the PD begins.

Total Count: The number of ping tests conducted.

Failure Count: The number of tests where the ping failed to complete.

Restart Count: The number of times that the PoE port was reset.