Optional step: Set your devices to factory defaults from the OOB port

This section describes how to reset devices to factory defaults through the OOB port.

If your network consists of less than five or six switches and access points and you run into difficulties, it could be easier to reset all switches and access points to factory defaults rather than to perform extended troubleshooting, which could be time-consuming. Reconfiguring network profiles could go fast in most cases.

We recommend that you use the OOB port to reset your devices to factory defaults so that you do not lose connectivity or are locked out from the controller during the reset process. In this example procedure, we are using an IP address of 10.51.100.25 and a subnet mask of 255.255.255.0 for the OOB port. The IP address of the default gateway 10.51.100.1.

CAUTION: Resetting your devices to factory default causes a major network interruption.

To configure the OOB port and then reset all your devices to factory defaults:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.

    The Managed Devices page adjusts.

  4. Configure a static IP address for the OOB port:
    1. Select Site Settings > Management VLAN and OOB.

      The Management VLAN page displays.

    2. From the menu in the left panel, select OOB.

      The OOB page displays.

    3. For the switch for which you want to configure the OOB port, select the Static check box.

      By default, the OOB port receives IP address settings from the DHCP server.

    4. In the IP Address field, enter 10.51.100.25, in the Subnet Mask field, enter 255.255.255.0, and in the Default Gateway field, enter 10.51.100.1.
    5. Click the Apply button.

      A pop-up window displays.

      CAUTION: When you click the Yes button, the OOB port is disconnected and you must reconnect using the new IP address settings.
    6. Click the Yes button.

      Your changes are saved.

  5. Log in to the OOB port with its new IP address.

    You might need to change the TCP/IP settings on the your computer on which the controller is installed.

  6. Reset a device to factory defaults:
    1. In the Managed Devices table, for the device that you want to set to factory defaults, click the Configure button.

      The Overview page displays.

    2. Select Maintenance.

      The Maintenance page displays.

    3. Click the Factory Default button.

      A pop-up window displays a warning.

      CAUTION: This process erases all your custom settings, including your network profile assignments and any custom profile templates.
    4. In the pop-up window, click the Confirm button.

      The factory default reset process starts. During the reset process, do not power down the switch. The switch reboots and restarts with factory default settings. When the process is complete and the switch receives an IP address from the DHCP server in the network, the controller can rediscover the switch. If the switch requires a static IP address, you first must set the IP address of the switch before the controller can rediscover the switch.

  7. To return to the Devices page of the controller, select Devices Management.
  8. Repeat 5 for the next device that you want to reset to factory defaults.

After a few minutes, the devices that you reset to factory defaults display in the Discovered Devices table, and you start the onboarding process for these devices. It might take up to 10 minutes for an access point to display in the Discovered Devices table.

For more information about onboarding and configuring, see the NETGEAR Engage Controller User Manual.