4. Check the status of the fiber modules

This section describes how to check fiber module status and diagnostics.

You can check the status of the fiber modules (also referred to as transceiver modules) and check for transmit faults, loss of signal, fault status, and, if available, diagnostic information.

If errors are discovered, you can remedy the situation. Often this means checking the SFP port, fiber module, and cable connections and, if needed, cleaning the SFP port and fiber module and reestablishing proper connections.

To check the status of the fiber modules:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.

    The Managed Devices page adjusts.

  4. Select Network Monitoring > Fiber Modules.
    The Fiber Modules page displays.
  5. To narrow down the information that displays or search for a switch name, switch model, network profile, or VLAN ID, do the following:
    • Device name: Click in the Device Name field, select the check box for one or more switch names, and then click the Apply button.
    • Device model: Click in the Device Model field, select the check box for one or more switch models, and then click the Apply button.
    The information in the table adjusts.
  6. To search for a port, in the Port field, type the port number format unit number/slot number/port number.

    The information in the table adjusts.

    The table provides a lot of information for each fiber module. The following fields are of particular interest when you are troubleshooting fiber modules.

    Table 1. Fiber module troubleshooting
    Field Normal condition Error condition
    Link State Up Down
    Link Speed Maximum speed that the fiber module and device at the other end supports Below maximum speed
    Output Power (dBm) Minimal attenuation (not below -10dBm) Excess attenuation (below -10dBm)
    Input Power (dBm) Minimal attenuation (not below -10dBm) Excess attenuation (below -10dBm)
    TX Fault No faults Faults occurred
    LOS No loss of signal Loss of signal occurred
    Fault Status No faults Faults occurred
    Diagnostics Info No diagnostics information Diagnostics information present