About PTP residency time stamping and network profiles

PTP residency time stamping uses the PTP end-to-end transparent clock (TC) of the switch. Whether a network profile supports it, and whether it is on by default, depends on the profile.

You can turn PTP residency time stamping on or off for each network profile (see Add a network profile). For the default setting of each profile, see Overview of preconfigured AV profile templates.

You can also turn PTP TC on or off for a single switch on the TC Switches tab.

The following network profiles do not support PTP residency time stamping, and you cannot configure it in the controller UI:

  • Audio-Video AVB (AVB uses gPTP, which is incompatible with PTP residency time stamping)
  • Data
  • Lighting
  • NUCLEUS Converged AV Network
  • Sonos
  • Video
  • Video NDI4
  • Visionary AV Network
Note: PTP residency time stamping is not supported in a stacking configuration or on M4300 series models M4300-24X24F, M4300-48X, and M4300-48XF.