Set a fixed IP address for the OOB port

By default, no IP address is set for the OOB port and the DHCP client is enabled. You can disable the DHCP client for the OOB port and set a fixed (static) IP address.

To set a fixed IP address for the OOB port:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select the check box to display Physical Devices and/or Virtual Devices.
    By default, all managed devices display. Use the Device Model menu to select individual devices.
  5. In the table, for the device that you want to configure, click the Configure button.

    The Overview page displays.

  6. In the Device Details section, below the OOB IP Address field, click the pencil icon.

    The Edit OOB IP Address window displays.

  7. From the OOB IP Settings menu, select Static and specify the following settings:
    • OOB IP Address: The static IP address for the OOB port. By default, no IP address is set for the OOB port.
    • Subnet Mask: The IP subnet mask for the OOB port. By default, no subnet mask is set for the OOB port.
    • Default Gateway: The gateway through which the OOB port can be reached. By default, no IP address is set for the default gateway.
    Warning: If you are logged in to switch over the OOB port, when you click the Apply button, you are disconnected and need to log in to the switch at the new IP address.
  8. Click the Apply button.

    Your settings are saved. The window closes. The Overview page displays again.

  9. To save the settings to the running configuration, at the top right of the page, click the Save button.
  10. To return to the Devices page of the controller, select Devices Management.