Perform a cable test

You can test and display information about the cables that are connected to switch ports.

Note: This option is not supported on the M4500 series switches.

To perform a cable test:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select the check box to display Physical Devices and/or Virtual Devices.
    By default, all managed devices display. Use the Device Model menu to select individual devices.
  5. In the table, for the device that you want to configure, click the Configure button.

    The Overview page displays.

  6. Select Diagnostics > Cable Test.
    The Cable Test page displays.
  7. Select the ports for which you want to test the attached cables.
  8. Click the Test Selected Ports button.

    A cable test is performed on the selected ports. The cable test might take up to 30 seconds to complete. If the port forms an active link with a device, the cable status is Normal.

    The following table describes the test results that might display in the Cable Test Results section.
    Field Description

    Port

    The port on which the test was performed

    Test Results

    Normal: The cable is working correctly.

    Open: The cable is disconnected or has a faulty connector.

    Short: An electrical short occurred in the cable.

    Cable Test Failed: The cable status could not be determined. The cable might in fact be working.

    Untested: The cable is not yet tested.

    Invalid cable type: The cable type is unsupported.

    No cable: No cable is detected.

    Fault Distance

    The estimated distance in meters from the end of the cable to the failure location. The failure location is displayed only if the cable status is Open or Short.

  9. To return to the Devices page of the controller, select Devices Management.