Configure a PTPv2 boundary clock/grandmaster clock

Note: The PTPv2 boundary clock/grandmaster clock feature is supported on M4350 series models M4350-16V4C and M4350-40X4C only.

Note the following about the PTPv2 boundary clock (BC)/grandmaster (GM) clock feature:

  • If a network profile that uses AVB is enabled (for example, a network profile that is based on Audio AVB), the PTPv2 BC clock (or transparent clock) is automatically disabled and you cannot manually enable the feature. AVB and a PTPv2 BC/GM cannot coexist.
  • A PTPv2 BC/GM is not supported on a stack.

To globally enable and configure the PTPv2 BC/GM feature on model M4350-16V4C or model M4350-40X4C:

  1. On your computer, in the folder in which you installed the controller application, double-click the Engage application icon, or double-click the Engage shortcut.

    The controller application opens and displays a login page.

  2. In the Login Name field, enter admin as the user name, in the Password field, enter the controller password that you set up the first time that you logged in, and click the Login button.

    The Managed Devices page displays.

  3. If you set up more than one site, from the Site menu, select the site.

    The Edit Network Setup pop-up window displays.

    Do one of the following:

    • Make no changes to the network setup for the site: Click the Apply button.
    • Change the network setup for the site: See the information in Edit the network setup of a site. When you are done, click the Apply button.

    The Managed Devices page adjusts.

  4. Select the check box to display Physical Devices and/or Virtual Devices.
    By default, all managed devices display. Use the Device Model menu to select individual devices.
  5. In the table, for the device that you want to configure, click the Configure button.

    The Overview page displays.

  6. Select Network Profiles.
    The Network Profiles page displays.
  7. Below the graphical display of the switch, to the right of PTPv2 BC/GM, click the 3 dots icon.

    The PTPv2 BC/GM Setting pop-up window displays.

  8. Turn on the PTPv2 BC/GM toggle so that it displays green and is positioned to the right.

    The windows adjusts to display the grandmaster clock settings.

    By default, the toggle is turned off, displays gray, and is positioned to the left.
  9. Configure the following grandmaster clock settings, for which the default settings depend on the selected clock profile:
    1. PTPv2 Profile: Depending on your network needs, select one of the following clock profiles:
      • Default: The default PTPv2 settings are used. This is the default setting.
      • AES67: A clock profile for connecting audio devices over a common PTP profile.
      • SMPTE-2059-2: A clock profile for video traffic.
      • AES-R16-2016: A clock profile that interoperates between SMPTE and AES67 clock profiles.
    2. Clock Type:
      • One-Step: The clock timestamps the Sync message as it exits the port.
      • Two-Step: The clock timestamps the Sync message as it exits the port and then immediately follows up with another message that captures the egress timestamp of the Sync message. This is the default setting.
    3. PTP Domain: Select a value from 0 to 127.

      A PTP domain consists of one of more ordinary or boundary clocks that communicate with each other, and a single grandmaster clock. Although more than one switch can be capable of functioning as a grandmaster in the network, only one switch can the active grandmaster clock. The default setting is 0, except for the SMPTE-2059-2 PTPv2 profile, for which the default settings is 127.

    4. IPv4 Address: Type the IPv4 address of the port that functions as the boundary or grandmaster clock.
    5. Local Clock Prority1: Select a priority value from 0 to 255. The priority 1 determines which switch that is capable of functioning as a grandmaster clock is elected to be the active grandmaster clock in the network.
    6. Local Clock Prority2: Select a value from 0 to 255. The priority 2 also determines which switch that is capable of functioning as a grandmaster clock is elected to be the active grandmaster clock in the network.
    7. Announce Interval: This is the period between successive Announce messages in logarithm to base 2 format. The value that you can select depends on the selected PTPv2 profile:
      • Default: 0 to 4. The default setting is 1.
      • AES67: 0 to 4. The default setting is 1.
      • SMPTE-2059-2: –3 to 1. The default setting is 0.
      • AES-R16-2016: 0 or 1. The default setting is 0.
    8. Announce Timeout: This is the number of Announce messages that are not acknowledged before the switch determines that the grandmaster clock is not transmitting. Select a value from 2 to 10. The default setting for all PTPv2 profiles is 3. For the AES-R16-2016 profile, the only possible value is 3.
    9. Sync Interval: This is the period between successive Sync messages, in logarithm to base 2 format. The value that you can select depends on the selected PTPv2 profile:
      • Default: –1 to 1. The default setting is 0.
      • AES67: –4 to 1. The default setting is –3.
      • SMPTE-2059-2: –7 to –1. The default setting is –3.
      • AES-R16-2016: –4 to 1. The default setting is –3.
    10. Delay-Request Interval: This is the period between successive Delay-Request messages from the boundary clock to the grandmaster clock, in logarithm to base 2 format. Delay-Request messages help to calculate the path delay. The value that you can select depends on the selected PTPv2 profile:
      • Default: 0 to 5. The default setting is 0.
      • AES67: –3 to 5. The default setting is 0.
      • SMPTE-2059-2: –7 to 4. The default setting is –3.
      • AES-R16-2016: –4 to 5. The default setting is –3.
  10. Click the Apply button.

    Your setting are saved.

  11. To save the settings to the running configuration, at the top right of the page, click the Save button.
  12. To return to the Devices page of the controller, select Devices Management.